Troubleshooting¶
Find the symptom, check the likely cause, apply the fix. Low-level connection analysis (counters, unsolicited frames, packet capture) is on Transport Diagnostics.
| Symptom | Section |
|---|---|
| Container unhealthy or unreachable | Unhealthy container |
| Service refuses to start | Start refused |
Cannot log in as admin | First admin login |
/docs answers 404 | /docs 404 |
| Write, dispatch or Energy Manager routes answer 404 | Writes 404 |
| 429 Too Many Requests | 429 |
503 device_maintenance | Maintenance |
| Mixed, stale or missing values | Stale values |
| Read timeouts, reconnects, unexpected frames | Connection drops |
| Charging plan shows no plan | Plan status |
The container is unhealthy or unreachable¶
- Likely cause: the service listens on loopback inside the container, or
BIND_PORTdiffers from the container side of the port mapping (also after changing the port in the GUI). A loopback bind in a container logs a warning at start. - First check:
docker compose -f docker/compose.yaml logs rct-apifor the bind warning. - Fix: set
BIND_ADDRESS=0.0.0.0and the GUI option "behind reverse proxy", and keepBIND_PORTequal to the container port of the mapping. See Docker and Network and TLS.
The start is refused¶
- First check:
python -m app validate(ordocker compose -f docker/compose.yaml run --rm rct-api validate). - Typical causes and fixes:
- a GUI device list with more than one device without network id on the same endpoint: give each device its own endpoint or network id;
- an invalid object registry or write allowlist: fix the entry the validation names;
- missing
HMAC_SECRETin a read-only container, or a secret that differs from the one that encrypted the existing database: set the original secret.
First admin login¶
- Likely cause: the generated
adminpassword is printed once, in the boxedFIRST STARTblock on stdout, when the admin account is created; restarts neither show nor replace it. - First check: the logs of the first start.
- Fix: if missed, there is no file to read it from: reset the admin account. The first login requires a password change. Keep database and
HMAC_SECRETtogether when restoring a backup.
/docs answers 404¶
- Cause:
/docsand/openapi.jsonare served only withDOCS_PUBLIC=true. - Fix: set
DOCS_PUBLIC=true.
Write endpoints answer 404¶
- Cause: write access is off (GUI Inverters page); the write, dispatch and Energy Manager routes answer 404
write_disabled. - Fix: switch write access on. It takes effect at once, without a restart.
429 from many clients behind a proxy¶
- Likely cause: all callers share the proxy address, so they share one rate-limit budget.
- Fix: set
TRUSTED_PROXIESandFORWARDED_HEADER; see Network and TLS. - Admin GUI: it backs off by itself on a 429 and honours
Retry-After; its requests use the separateADMIN_SESSION_RATE_LIMIT_*budget (see Environment).
503 device_maintenance¶
- Cause: the inverter signalled its bootloader.
- Fix: none needed. Requests resume after the cool-down once a single read succeeds.
Mixed or stale values¶
- Likely cause: another client (vendor app, home automation) uses port 8899, or a second instance runs against the same inverter.
- First check:
foreign_access_suspectedinGET /api/v1/readiness. - Fix: stop the other client or instance; see Operation. Values carry
stale,sourceandage_seconds.
Read timeouts, reconnects or unexpected frames¶
- Likely cause: line noise, a network problem, another client, or periodic subscriptions that the inverter kept from an earlier session. The log shows "Connection to ... dropped: no response to object ..." or
Unsolicited response burst started. - First check:
GET /api/v1/readiness(periodic_available,periodic_setup_failures,foreign_access_suspected) and therct_transport_*metrics. - Fix: remove foreign access first. For counters, packet capture and the timeout runbook see Transport Diagnostics.
Charging plan shows no plan¶
- Likely cause: a planner precondition is missing. The status names it:
battery_state_unavailable,spot_disabled,spot_prices_unavailable,solar_not_configuredorsolar_forecast_unavailable. - First check: the readiness checklist on the Charging plan tab.
- Fix: enable and configure the spot market and weather forecast, connect the inverter, or set an Expert capacity override. Meaning of each status: Planner status codes.