Skip to content

Consumption History and Daily Backfill

How the service records household consumption, how the inverter's own daily log fills gaps, and which data may train the consumption forecast. Part of the Energy Manager; consumption data feeds the charging plan preview.

Question Answer
Where does the data come from? The household_load_power value the service already reads, plus the inverter's daily load logger for missed days.
Extra inverter reads for the 15-minute history? None. A passive observer reuses the periodic read path.
How long is it kept? 15-minute buckets: rolling 60 days. Daily totals: the last 60 completed local days.
Which source trains the forecast? Local 15-minute measurements only.

Consumption backfill

The backfill closes gaps in the daily consumption record. It never invents quarter-hour data.

flowchart LR
    LOC["Local 15-minute measurements<br/>household_load_power"] --> FC[Consumption forecast learning]
    LOC --> DAY["Exact daily total<br/>local day coverage 90 % or more"]
    LOG["Inverter daily logger<br/>logger_day_eload_log_ts"] --> MISS["Daily totals for missing days only"]
    MISS --> DAY
    LOG -.->|never trains| FC
    LOG -.->|never split into 15-minute buckets| LOC

The backfill never fabricates quarter-hour measurements and never trains the consumption forecast.

Source Daily total Forecast learning 15-min profile
Local 15-minute measurements yes yes yes
Inverter daily history yes no no

Contract:

  • The backfill is always on and read-only: it uses the normal device queue and needs no write permission.
  • It covers completed local calendar days only, never the running day, for the last 60 days.
  • Local complete measurement wins. A day counts as locally measured at 90 % or more local-second coverage; otherwise a stored inverter total is used. The sum of both is never taken.
  • Only days that are neither measured locally nor stored yet are fetched. The values the inverter provides go to consumption_daily_history; everything else stays unavailable.
  • The inverter day history is never decomposed into artificial quarter-hour buckets (profile_available is false for such days).
  • Days are local calendar dates of the site time zone; a 23 h or 25 h DST day is still one date.

When it runs

A background service starts shortly after the service start, after an outage and about once a day. It repairs multi-day outages and bootstraps the daily history of a new installation.

Device query behaviour

The history query is not a register write, but it is a request frame with a timestamp. A firmware that ignores it makes the request time out. The transport keeps the connection for other objects after the first miss, re-reads that object on a new connection and reconnects on a second miss in a row; the service then backs off for six hours.

Logger semantics (hardware observations)

logger_day_eload_log_ts is verified on hardware; see Hardware Verification.

Property Observed behaviour
Unit and day Wh per local calendar day
Timestamps Local wall-clock fields, labelled UTC
before= query boundary On the tested inverter, the 2026-10-18 A/B returned the boundary point only when local wall-clock fields were encoded as UTC
Duplicate points The logger may repeat one day's 23:59:59 point 8 to 16 times with values differing by under 1 Wh; the largest value wins

Jitter within 5 Wh or 0.5 % is logged at debug level; only a larger spread logs a warning with the minimum and maximum.

before= A/B on the tested inverter

  • A: true UTC instant 1792101600 as before=: the 2026-10-15 day point was missing.
  • B: local wall-clock 1792108800 encoded as UTC: the point was present at 18018.6797 Wh.
  • The result matched the operator's export and repeated the earlier comparison. It confirms this encoding on the tested inverter only; other device/firmware combinations still need verification.

tools/probe_consumption_history.py repeats this check read-only on a real inverter.

15-minute measurement history

The service builds a local history of the household_load_power metric. It does not depend on QuestDB, InfluxDB or metrics export. A passive observer buffers each value; a background task integrates the samples into fixed 15-minute energy buckets off the receiver path and writes them to the consumption_history_intervals SQLite table (one row per device and quarter hour). A SQLite error there never disturbs the inverter connection or the read cache.

Rule Value
Integration Time-weighted: Wh = W x hours, split across any 15-minute boundary
Measurement gap A negative, non-finite or missing reading adds no energy and no sample count; integration never bridges it
Maximum integration gap 5 minutes; a longer dropout leaves the period uncovered
Per-bucket quality sample_count and coverage_seconds (at most 900 s)
Missing samples Never read as 0 W
Retention Rolling 60 days (code default); pruning touches only the consumption table

Counter capture

app/optimizer/meter.py differences the cumulative load counter energy_e_load_total (Wh, float32) into 15-minute buckets next to the integrated household_load_power. A HistoryBucket has a quality:

Quality Meaning
COMPLETE at least 810 s measured
PARTIAL at least 600 s measured
ESTIMATED gap of 300 s to 24 h spread as a flagged estimate
MISSING no usable data

A gap of at most 300 s is measured. Counter resets, deltas above 50 kW, stalled counters and gaps over 24 h are rejected and counted; the day counter is the fallback. Nothing beyond "non-decreasing between resets" is assumed about the counter; open points are listed in Hardware Verification.

Daily consumption API

Both routes read the local store only and never access the device. Full parameters: API endpoints.

Route Purpose
GET /api/v1/devices/{device_id}/consumption/day?date=YYYY-MM-DD One local day
GET /api/v1/devices/{device_id}/consumption/days?from=...&to=... A range of at most 60 days

source is one of:

source Meaning
local_measured 15-minute profile available
inverter_history Day total only, profile_available false
unavailable energy_wh is null; the running day is always unavailable

The Charging plan tab shows the same data as a bar chart of the last 60 completed days (green: locally measured, blue: inverter day total, gap: unknown) with the daily average over known days, fed by GET /admin/api/energy/devices/{device_id}/consumption-history (local store only). While no day has data, the whole section stays hidden.

Forecast learning versus daily reconciliation

Two separate mechanisms use consumption data:

Forecast learning Daily reconciliation
Purpose Predict the next day for the charging plan Keep an exact daily total, also for missed days
Input Clean, closed, sufficiently measured local 15-minute buckets Local totals, inverter daily history for gaps
Inverter day history Never used Used for missing days only

The forecast is deterministic, without machine learning. It separates the everyday profile (a capped mean per local weekday and quarter hour) from the current consumption phase:

  • A contiguous stretch of clearly reduced consumption is labelled suspected low activity (never "absence"). The profile is then frozen and the forecast follows the low level.
  • Several consecutive well-measured observations resembling the profile return the forecast to it; a single spike or heavy appliance does not.
  • Estimated buckets and outages are neither vacation nor zero consumption.
  • Lasting changes are learned via a level factor (about three days) or, after four weeks, by promoting the phase to the new normal.
  • Fewer than 14 usable days: median forecast (same weekday, then time of day, then whole history) at low confidence. No usable history: the configured baseline_household_load_w as an explicit low-confidence bootstrap assumption, never presented as measured.
  • The next local day (92 to 100 slots) is stored once per day after 22:00 local time with its basis and later compared with measured actuals.

Algorithm, thresholds and measured behaviour: Consumption Forecast.