Energy Manager

The Energy Manager turns one business decision ("charge to 80 % now") into a battery dispatch command. The admin GUI page Energy Manager and the REST API share one control path. Around it sit read-only inputs (spot prices, solar forecast, consumption history) and a read-only charging plan preview that proposes when to charge from the grid.

Energy Manager spot-market configuration and day-ahead price preview

  • Charging Plan


    Read-only preview of when to charge from the grid, from prices, solar and consumption forecast.

    Charging Plan

  • Consumption


    15-minute measurement history, daily backfill from the inverter's logger, forecast learning.

    Consumption

  • Battery Control


    Off / Manual / External, write access, hardware verification gates, charge limits.

    Battery Control

  • Hardware Verification


    What is verified on real hardware and what is not.

    Hardware Verification

What writes to the inverter, and what does not

Component Writes to the inverter? Purpose
Spot Market No Day-ahead prices for the dashboard and the plan
Weather No Solar production forecast for the dashboard and the plan
Consumption history and backfill No (read-only queries) Household consumption record and forecast
Charging plan No Read-only charging plan preview (Dry-Run); proposes a schedule
Energy Manager actions (charge, discharge, hold, auto) Yes, behind four gates Battery dispatch
flowchart LR
    subgraph IN["Read-only inputs"]
        SP[Spot prices]
        SOL[Solar forecast]
        CON[Consumption forecast]
        BAT[Battery state]
    end
    IN --> OPT[Pure optimizer]
    OPT --> PLAN[Read-only plan<br/>preview]
    OP[Operator or external app] --> EM[Energy Manager]
    EM --> GATES{{Safety gates}}
    GATES --> DISP[(Battery dispatch)]
    PLAN -.->|no connection| DISP

Charging plan in short

The planner reads local data only (persisted spot prices, solar forecast, the consumption forecast and the current battery state), simulates the battery without grid charging, and places the grid energy needed to protect the reserve into the latest permitted slots. It sends no inverter command: no automatic executor, no Dynamic operating mode, no register write.

Input Source
Spot prices Energy-Charts, stored in SQLite
Solar forecast Open-Meteo, stored in SQLite
Consumption forecast Local 15-minute history, adaptive or median
Battery state SoC from the read cache, verified usable capacity, configured power limits

Details, status codes and the preview API: Charging Plan.

Usable battery capacity

The plan needs a verified current usable capacity or an Expert override. Module count gives a rated 100 % reference, while live Ah readings have not proven current capacity. Without an override it reports battery_state_unavailable. See Usable battery capacity.

Consumption in short

The service keeps its own 15-minute household_load_power history (no additional inverter reads, rolling 60 days). The inverter's daily load logger fills missed days with daily totals only; it never becomes quarter-hour data and never trains the forecast. Details: Consumption.

Safety model

Gate Switch
1. Write access Inverters page, global; choosing a mode never turns it on
2. Operating mode Off / Manual / External, per inverter
3. Hardware verification Per-device capabilities verified automatically in the background; an Expert override remains available
4. Dispatch Charge power clamped to the configured limit, commands expire after one hour

Battery control is off until you enable and verify it

A newly added inverter has no confirmed mode. Commands answer 409 energy_manager_off until an operator selects Manual or External in the GUI. The charging plan bypasses none of these gates because it never dispatches. Flow and details: Battery Control.

Modes in short

Mode Who may command Use
Off Nobody; the inverter runs its Internal SoC strategy Default and hand-back
Manual The admin GUI (charge, keep idle, discharge) Operator control
External The REST API with a read/write token (POST /api/v1/devices/{id}/energy/command) Home automation or an external app

Actions, error codes, restore behaviour and the GUI layers: Battery Control.

Spot Market

In Energy Manager > Spot Market, choose a bidding zone and save it to the admin database. The source is disabled by default; currency and unit are read-only; network fees are not added.

The preview shows the zone's prices for yesterday, today and tomorrow. The source reports EUR/MWh; prices are normalized to EUR/kWh internally and shown as cents per kWh. Tomorrow's curve is published around 12:45 CET (SDAC auction), so it is normally absent in the morning. A complete day has 96 quarter-hour intervals (92 or 100 on daylight-saving days).

  • Intervals live in the SQLite spot_market_intervals table, the zone list in the admin database. The UI reads only from SQLite; page views, previews and restarts never call the provider.
  • One daily retrieval fetches tomorrow's prices (and the zone list) from 13:00 Europe/Berlin, only while tomorrow is missing; nothing is requested until the next day. Only an empty database (first start) also fetches today and yesterday.
  • A failed retrieval is retried with a growing delay (5 minutes up to 1 hour) and logged as a warning. While due data is missing, the preview and dashboard show a stale warning; an unpublished tomorrow counts as a failure only one hour after 13:00.
  • The table keeps only the current three local days, no history. If tomorrow is not published, its rows stay absent and the preview shows the availability hint. Inverter control is never affected.

Raw market price

The displayed price is the day-ahead market (exchange) price only. It is not a complete household electricity price: it excludes network fees, taxes, levies and supplier margin.

Admin routes /admin/api/energy/spot-market/config (GET, PUT), /admin/api/energy/spot-market/bidding-zones (GET) and /admin/api/energy/spot-market/preview (POST) require an admin session (writes also CSRF); they are not public token routes.

Weather and solar forecast

In Energy Manager > Weather, configure a solar production forecast from Open-Meteo. Like the spot market it is a read-only input and never charges or discharges the battery. It is disabled by default; a disabled or incomplete configuration makes no network request.

Type a city or postal code into the location search; the server resolves it through its geocoder (GEOCODING_PROVIDER operator setting: photon default, open_meteo legacy) and offers a short pick list. The forecast itself always runs on Open-Meteo. Choosing an entry fills in the coordinates, and the time zone when the geocoder reports one. Photon reports none, so local-time display then falls back to UTC; the forecast is always computed in UTC. The browser never calls the geocoder directly; every request goes through the admin API to the providers' fixed endpoints.

Describe your PV array so the forecast can turn irradiance into expected power:

Field Meaning
Location Latitude and longitude; a descriptive name is optional.
Peak power PV nameplate DC power, entered in kilowatt-peak (kWp), for example 10.0; stored internally in watt-peak (Wp).
Tilt Module angle from horizontal: 0 degrees flat, 90 degrees vertical.
Azimuth Open-Meteo convention: 0 = south, -90 = east, +90 = west, +-180 = north.
Performance ratio A single factor in (0, 1] (default 0.85) folding inverter, wiring, soiling and temperature losses into one transparent multiplier.

A disabled configuration may be saved incomplete; enabling it requires every forecast value. The model is deliberately simple and never patches a provider value: a missing, negative or mistyped reading is reported as an error.

flowchart LR
    GTI["Open-Meteo GTI<br/>W/m2, 15-min mean"] --> CONV["x peak power x performance ratio"]
    CONV --> PWR["PV power (W)"]
    PWR --> EN["Energy per 15-min slot (Wh)"]
    EN --> PREV[Weather preview]
    EN --> WIDGET[Dashboard solar widget]
    EN --> PLAN[Charging plan]

The preview shows the production curve and energy for the next 24 hours. Quarter-hour intervals (96 per local day, 92 or 100 on daylight-saving days) are stored in the SQLite solar_forecast_intervals table; no history is kept.

  • A background refresh replaces the contents with the latest three local days once per local day (when today or tomorrow is missing, so the next-24-hours figure is always backed by stored data).
  • A failed retrieval is retried with a growing delay and warned about in the log and, while data is missing, in the preview and dashboard.
  • Preview and dashboard read only from the table, never from the provider. Changing the saved configuration clears the previous rows before the refresh starts.

Admin routes /admin/api/energy/weather/config (GET, PUT), /admin/api/energy/weather/locations (GET, geocoding search) and /admin/api/energy/weather/preview (POST) require an admin session (writes also CSRF); they are not public token routes.

Attribution

The free Open-Meteo Open-Access endpoint needs no API key and is for non-commercial use under CC BY 4.0 ("Weather data by Open-Meteo.com"), with no availability guarantee. Location search attribution follows the active geocoder: Photon, "Location data from Photon © OpenStreetMap contributors" (ODbL); Open-Meteo geocoder, "Location data based on GeoNames via Open-Meteo". The Weather tab itself no longer displays these credits. The endpoints must not be polled aggressively (roughly 10,000 requests per day), so the forecast retrieval (once per local day) is fixed in code and the location search uses a short-lived server-side cache.

Where to go next

Topic Page
Plan inputs, policy, replanning, preview API Charging Plan
Measurement history, backfill, daily consumption API Consumption
Modes, actions, gates, restore, GUI Battery Control
REST routes API endpoints
Verified versus unverified hardware behaviour Hardware Verification
Forecast algorithm Consumption Forecast